Search
retinal imaging
Indications:
- screening for diabetic retinopathy
Procedure:
- IDx-DR device analyzes images of the retina taken with the Topcon NW400 retinal camera
- physician uploads the digital images of the patient's retinas to a cloud server with the IDx-DR software
Interpretation:
if images of sufficient quality, 1 of 2 results reported
1) more than mild diabetic retinopathy detected: refer to an eye care professional
2) negative for more than mild diabetic retinopathy; rescreen in 12 months
* sensitivity 87%, specificity 90% [1]
Related
retinal camara
General
imaging
References
- Brooks M
FDA OKs AI Device to Detect Diabetic Retinopathy in Primary Care.
Medscape - Apr 11, 2018.
https://www.medscape.com/viewarticle/895061
- FDA News Release. April 11, 2018
FDA permits marketing of artificial intelligence-based device
to detect certain diabetes-related eye problems.
https://www.fda.gov/NewsEvents/Newsroom/PressAnnouncements/ucm604357.htm