implantable cardioverter defibrillator (ICD)

Implantable device to automatically detect & terminate ventricular tachycardia or ventricular fibrillation by delivering or more shocks to the heart to terminate the arrhythmia. Indications: 1) *serious arrhythmias not controlled by medication* - hemodynamically significant ventricular arrhythmia [2] - ventricular fibrillation, cardiac arrest 2) *risk of arrhythmia due to underlying heart disease# - cardiomyopathy with LVEF <= 35% [25] 3) NYHA class II or III heart failure + - predicted survival > 1 year + - ischemic cardiomyopathy > 40 days post MI or non-ischemic cardiomyopathy with LV ejection fraction <= 35% or - history of hemodynamically significant ventricular arrhythmia or cardiac arrest [2] - candidates for left ventricular assist device or cardiac transplantation (out of hospital) [32] 4) ischemic cardiomyopathy with NYHA class I-III heart failure & LV ejection fraction <= 30% [2] 5) for class III or IV NYHA heart failure & ECG QRS duration > 120 msec, cardiac resynchronization therapy with defibrillator indicated [2] 6) hereditary predisposition to fatal arrhythmias - hypertrophic cardiomyopathy 7) high-risk features for sudden death & LVEF < 45% [42] - pulmonary sarcoidosis insufficienty high risk [2] 8) sustained ventricular arrhythmias (> 30 seconds) [2] 9) cardiac arrest without reversible etiology [2] 10) subcutaneous ICD recommended for patients with inadequate vascular access or high infection risk from an ICD, & for whom pacing is not required [32] 11) > 40 days since myocardial infarction or > 3 months since PCI or CABG [2] (see Procedure: below) * The multicenter automatic defibrillator implantation trial (MADIT) showed better survival in patients with inducible ventricular tachycardia with implanted defibrillators than those treated with anti-arrhythmic agents. # ICD may benefit patients with history of myocardial infarction & low LV ejection fractions (< 30-35%) > 40 days after MI. [3,5] * may benefit younger patients (HR=0.65) but not older patients [11] # Life expectancy should be > 1 year Contraindications: - patients with new onset heart failure* [2] - no survival benefit for patients with severe LV dysfunction [11] - no benefit for renal dialysis patients unless LVEF < 35% [37] * left ventricular function may recover [2] Procedure: - these devices may be installed without thoracotomy - some devices have back-up bradycardia & anti-tachycardia pacing - devices are installed in the cardiac catherization laboratory - after electrode placement & testing, a small generator (circuitry, capacitor, battery) is place under the skin in the chest - subcutaneous ICD (without pacemaker) FDA-approved Sept 2012 [17] - no differences in complications or mortality among patients with subcutaneous vs transvenous ICD [39] - the device records when arrhythmias occur & shocks are delivered - battery life of 3-5 years - shocks may occur during sinus rhythm or atrial fibrillation - overall 1 year survival 90% - dual-chamber ICDs are associated with significantly more implant complications & no improvement in outcomes relative to single-chamber devices [21] - placement should be delayed until 40 days post-MI [2] or 3 months after percutaneous coronary intervention (PCI) - echocardiogram prior to ICD placement [44,45] - ICD placement prior to hospital discharge if post MI ventricular tachycardia > 24 hours post MI - routine defibrillation testing may increase complications without improving outcomes [24] Complications: 1) infection a) originate in subcutaneous pocket created for generator box b) etiologic agents - coagulase-negative Staphylococcus - Staphylococcus aureus c) management: - removal of the generator box - do NOT aspirate device pocket - may damage leads or introduce infection [2] - systemic antibiotics for 2 weeks - epicardial & transvenous wires - should also be removed if possible - if not, 6 weeks of antibiotic therapy 2) device malfunction [6,8] - inappropriate shocks increase mortality [9] - women have fewer appropriate shocks and more lead complications [16] 3) electromagnetic interference a) avoid metal detection devices at airports, courthouses ... b) cell phones may be used, but it is prudent to keep cellphone on opposite side of body from ICD c) avoid magnets or strong magnetic fields, i.e. MRI is contraindicated - MRI-conditional devices are those that that FDA has determined do not pose additional hazards under prespecified conditions - older ICDs (pre-2015) with asynchronous pacing capabilities (although not MRI-conditional devices) also generally safe with MRI [33,43] d) iphone 12 circular array of magnets around a central charging coil may interfere with function of ICD [40] e) common electromagnetic devices may interfere with operation of defibrillators - these include Apple iPhone 12, Apple AirPods Pro & their wireless charging case, Microsoft Surface Pen, & Apple Pencil 2nd generation [41] 4) failure to prevent sudden death - recurrent myocardial infarction & cardiac rupture account for 50% of deaths after myocardial infarction [10] 5) perforation of the ventricular wall by ICD lead causing pericarditis, pericardial effusion, hemopericardium, pleural effusions & hemothorax [27] 6) venous thrombosis, possibly superior vena cava syndrome [35] 7) 6.1 complications/100 patient-years follow-up [30] - 2.6/100 require reoperation (generally device malfunction, infection) - risks higher with cardiac resynchronization therapy- defibrillator (CRT-D) devices vs single-chamber devices [30] 8) brief episodes of atrial tachyarrhythmia are not associated with increased risk for stroke or other cardiovascular events [31] 9) patients with chronic kidney disease & heart failure have greater risk of hospitalization for heart failure with than without ICD (17 vs 11/100 person years) [34] 10) inappropriate shock more likely in elderly with multiple corbidities (RR=2.1) when implanted for primary prevention [38] Management: 1) monitoring needed 2) programming of ICDs to prevent inappropriate therapy for supraventricular tachycardia & nonsustained ventricular tachyarrhythmias: [18] a) reduces unnecessary shocks b) improves survival c) does not increase the frequency of syncope [18] 2) amiodarone effectively blocks many ICD shocks [6] 3) metal detectors (hand-held & gates) used at airports are "probably safe" for patients with cardiac pacemakers or implantable cardioverter-defibrillators (ICDs) [13,15] 4) many patients with ICDs can safely participate in vigorous sports [20] 5) surgery: perioperative management - shock therapy should be turned off - electrocautery during surgery cause the ICD to interpret the electrical activity as ventricular fibrillation & initiate a shock [2] - pacing function should be change to asynchronous mode [2] - the asynchronous mode allows the pacing to continue regardless of cardiac electrical activity or electrocautery [2] 6) see ICD driving guidelines Notes: 1) 20% of implantable cardioverter-defibrillators are placed contrary to evidence-based guidelines [12] - use of carvedilol rather than metoprolol associated with lower rate of inappropriate ICD placement [23] 2) < 10% of eligible older adults receive ICDs within 1 year after myocardial infarction [26] 3) implantable cardioverter-defibrillators (ICDs) & cardiac resynchronization therapy (CRT) devices often include a feature that measures intrathoracic impedance, potentially providing an early warning system for decompensation by detecting pulmonary fluid retention [14] 4) explanted ICDs can be reused safely to help people who otherwise would not be able to afford them [19] 5) may be covered by Medicare [5] 6) potential cybersecurity vulnerabilities with Medtronic's implantable cardioverter defibrillators (ICDs) & cardiac resynchronization therapy defibrillators (CRT-Ds) [36] - wireless telemetry system used for communication does not use encryption, authentication, or authorization [36]

Related

cardiac device infection cardiac pacemaker cardiac resynchronization therapy ICD driving guidelines multicenter automatic defibrillator implantation trial (MADIT)

Specific

automatic implantable cardioverter/defibrillator (AICD)

General

cardiovascular implantable electronic device (CIED) defibrillator

References

  1. Mayo Internal Medicine Board Review, 1998-99, Prakash UBS (ed) Lippincott-Raven, Philadelphia, 1998, pg 67, 68
  2. Medical Knowledge Self Assessment Program (MKSAP) 11, 15, 16, 17, 19. American College of Physicians, Philadelphia 1998, 2009, 2012, 2015, 2022 - Medical Knowledge Self Assessment Program (MKSAP) 19 Board Basics. An Enhancement to MKSAP19. American College of Physicians, Philadelphia 2022
  3. Journal Watch 22(9):67, 2002 Moss AJ et al, N Engl J Med 346:877, 2002
  4. Journal Watch 25(5):37-38, 2005 Hohnloser SH, Kuck KH, Dorian P, Roberts RS, Hampton JR, Hatala R, Fain E, Gent M, Connolly SJ; DINAMIT Investigators. Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction. N Engl J Med. 2004 Dec 9;351(24):2481-8. PMID: 15590950 - Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005 Jan 20;352(3):225-37. PMID: 15659722 - McClellan MB, Tunis SR. Medicare coverage of ICDs. N Engl J Med. 2005 Jan 20;352(3):222-4. No abstract available. PMID: 15659721 http://www.cms.hhs.gov/media/press/release/asp?Counter=1331 - Kadish A. Prophylactic defibrillator implantation--toward an evidence-based approach. N Engl J Med. 2005 Jan 20;352(3):285-7. No abstract available. PMID: 15659729
  5. Connolly SJ, Dorian P, Roberts RS, Gent M, Bailin S, Fain ES, Thorpe K, Champagne J, Talajic M, Coutu B, Gronefeld GC, Hohnloser SH; Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC) Investigators. Comparison of beta-blockers, amiodarone plus beta-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators: the OPTIC Study: a randomized trial. JAMA. 2006 Jan 11;295(2):165-71. PMID: 16403928 - Page RL. Antiarrhythmic drugs for all patients with an ICD? JAMA. 2006 Jan 11;295(2):211-3. No abstract available. PMID: 16403933
  6. Amin MS, Matchar DB, Wood MA, Ellenbogen KA. Management of recalled pacemakers and implantable cardioverter- defibrillators: a decision analysis model. JAMA. 2006 Jul 26;296(4):412-20. PMID: 16868299
  7. Torpy JM, Implantable Cardioverter-Defibrillators JAMA 2007, 297:1946 - Zimetbaum PJ A 59-year-old man considering implantation of a cardiac defibrillator JAMA 2007, 297:1946 PMID: 17473301
  8. FDA MedWatch Oct 16, 2007 Medtronic Sprint Fidelis Defibrillator Leads http://www.fda.gov/medwatch/safety/2007/safety07.htm#Fidelis
  9. Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, et al; MADIT II Investigators. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008 Apr 8;51(14):1357-65. PMID: 18387436 - Raitt MH. Implantable cardioverter-defibrillator shocks: a double-edged sword? J Am Coll Cardiol. 2008 Apr 8;51(14):1366-8. PMID: 18387437
  10. Pouleur A-C et al. Pathogenesis of sudden unexpected death in a clinical trial of patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. Circulation 2010 Aug; 122:597. PMID: 20660803
  11. Physician's First Watch, Nov 2, 2010 Massachessetts Medical Society http://www.jwatch.org Santangeli P et al, Meta-analysis: Age and Effectiveness of Prophylactic Implantable Cardioverter-Defibrillators Annals of Internal Medicine 2010, 153:592-599 PMID: 21041579 http://www.annals.org/content/153/9/592.abstract
  12. Al-Khatib SM et al. Non-evidence-based ICD implantations in the United States. JAMA 2011 Jan 5; 305:43. PMID: 21205965 http://jama.ama-assn.org/content/305/1/43.full - Kadish A and Goldberger J. Selecting patients for ICD implantation: Are clinicians choosing appropriately? JAMA 2011 Jan 5; 305:91. PMID: 21205971
  13. Kolb CK et al. Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators? J Am Coll Cardiol 2003 Jun 4; 41:2054-9. PMID: 12798581 - Jilek C et al Safety of Screening Procedures With Hand-Held Metal Detectors Among Patients With Implanted Cardiac Rhythm Devices A Cross-sectional Analysis Annals of Internal Medicine November 1, 2011. 155(9):587-592 http://www.annals.org/content/155/9/587.abstract
  14. Journal Watch Massachusetts Medical Society Journal Watch Cardiology November 30, 2011 http://cardiology.jwatch.org
  15. Jilek C et al Safety of screening procedures with hand-held metal detectors among patients with implanted cardiac rhythm devices: A cross-sectional analysis. Ann Intern Med 2011 Nov 1; 155:587 PMID: 22041947
  16. MacFadden DR et al. Sex differences in implantable cardioverter-defibrillator outcomes: Findings from a prospective defibrillator database. Ann Intern Med 2012 Feb 7; 156:195. PMID: 22312139
  17. FDA News Release: September 28, 2012 FDA approves first subcutaneous heart defibrillator http://www.fda.gov/NewsEvents/Newsroom/PressAnnouncements/ucm321755.htm
  18. Moss AJ et al for the MADIT-RIT Trial Investigators. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med 2012 Nov 6 PMID: 23131066 http://www.nejm.org/doi/full/10.1056/NEJMoa1211107
  19. Pavri BB et al. Reuse of explanted, resterilized implantable cardioverter- defibrillators: A cohort study. Ann Intern Med 2012 Oct 16; 157:542 PMID: 23070487 - Farmer P and Bukhman G. Reuse of medical devices and global health equity. Ann Intern Med 2012 Oct 16; 157:591 PMID: 23070493
  20. Lampert R et al Arrhythmia/Electrophysiology. Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators. Results of a Prospective, Multinational Registry. Circulation. May 21, 2013 PMID: 23690453 http://circ.ahajournals.org/content/127/20/2021.full
  21. Peterson PN et al. Association of single- vs dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention. JAMA 2013 May 15; 309:2025 PMID: 23677314
  22. Crossley GH, Poole JE, Rozner MA et al The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management this document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Heart Rhythm. 2011 Jul;8(7):1114-54. PMID: 21722856
  23. Ruwald MH et al. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy: The MADIT-CRT Trial (Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy). J Am Coll Cardiol 2013 Oct 8; 62:1343 PMID: 23770172 - Raitt MH. Inappropriate implantable defibrillator shocks: An adverse outcome that can be prevented. J Am Coll Cardiol 2013 Oct 8; 62:1351. PMID: 23770170
  24. Hutsen L Routine Defibrillation Testing Not Required During ICD Implantation. Physician's First Watch, May 12, 2014 David G. Fairchild, MD, MPH, Editor-in-Chief Massachusetts Medical Society http://www.jwatch.org
  25. Al-Khatib SM et al. Association between prophylactic implantable cardioverter- defibrillators and survival in patients with left ventricular ejection fraction between 30% and 35%. JAMA 2014 Jun 4; 311:2209. PMID: 24893088
  26. Pokorney SD et al Implantable Cardioverter-Defibrillator Use Among Medicare Patients With Low Ejection Fraction After Acute Myocardial Infarction. JAMA. 2015;313(24):2433-2440. PMID: 26103027 http://jama.jamanetwork.com/article.aspx?articleid=2338252 - Hauser RG Underutilization of Implantable Cardioverter-Defibrillators in Older Patients. JAMA. 2015;313(24):2429-2430 PMID: 26103025 http://jama.jamanetwork.com/article.aspx?articleid=2338231
  27. Dudzinsk DM et al Case Records of the Massachusetts General Hospital. Case 19-2015. A 71-Year-Old Man with Chest Pain and Shortness of Breath. N Engl J Med. 2015 Jun 18;372(25):2438-46. PMID: 26083209 http://www.nejm.org/doi/full/10.1056/NEJMcpc1415757
  28. Russo AM, Stainback RF, Bailey SR et al ACCF/HRS/AHA/ASE/HFSA/SCAI/SCCT/SCMR 2013 appropriate use criteria for implantable cardioverter-defibrillators and cardiac resynchronization therapy: a report of the American College of Cardiology Foundation appropriate use criteria task force, Heart Rhythm Society, American Heart Association, American Society of Echocardiography, Heart Failure Society of America, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. J Am Coll Cardiol. 2013 Mar 26;61(12):1318-68 PMID: 23453819
  29. Greenspon AJ, Patel JD, Lau E et al 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol. 2011 Aug 30;58(10):1001-6 PMID: 21867833
  30. Ranasinghe I, Parzynski CS, Freeman JV et al Long-Term Risk for Device-Related Complications and Reoperations After Implantable Cardioverter-Defibrillator Implantation: An Observational Cohort Study. Ann Intern Med. Published online 3 May 2016 PMID: 27135392 http://annals.org/article.aspx?articleid=2520465
  31. Swiryn A, Orlov MV, Benditt DG et al Clinical Implications of Brief Device-Detected Atrial Tachyarrhythmias in a Cardiac Rhythm Management Device Population. Results from the Registry of Atrial Tachycardia and Atrial Fibrillation Episodes. Circulation. 2016;134:1130-1140. October 17, 2016 PMID: 27754946 http://circ.ahajournals.org/content/134/16/1130
  32. Young K, Fairchild DG Heart Groups Update Guidelines on Managing Ventricular Arrhythmias and Preventing Sudden Cardiac Death Physician's First Watch, Oc 31, 2017 David G. Fairchild, MD, MPH, Editor-in-Chief Massachusetts Medical Society http://www.jwatch.org - JACC article
  33. Nazarian S, Hansford R, Rahsepar AA Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices. N Engl J Med 2017; 377:2555-2564. December 28, 2017 PMID: 29281579 http://www.nejm.org/doi/full/10.1056/NEJMoa1604267
  34. Bansal N, Szpiro A, Reynolds K et al Long-term Outcomes Associated With Implantable Cardioverter Defibrillator in Adults With Chronic Kidney Disease. JAMA Intern Med. Published online February 5, 2018 PMID: 29404570 https://jamanetwork.com/journals/jamainternalmedicine/article-abstract/2671406
  35. DeFilippis EM, Vaidya A, Braun D et al A Shocking Turn of Events. N Engl J Med. 2018 May 24;378(21):e29. PMID: 29791827 https://www.nejm.org/doi/full/10.1056/NEJMimc1710576
  36. FDA Safety Communication. March 21m 2019 Cybersecurity Vulnerabilities Affecting Medtronic Implantable Cardiac Devices, Programmers, and Home Monitors: FDA Safety Communication. https://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm633960.htm
  37. Jukema JW, Timal RJ, Rotmans JI et al. Prophylactic use of implantable cardioverter-defibrillators in the prevention of sudden cardiac death in dialysis patients. Circulation 2019 Jun 4; 139:2628. PMID: 30882234 - Kaplan R, Passman R. Defibrillators don't deliver in dialysis. Circulation 2019 Jun 4; 139:2639. PMID: 31158000
  38. Hajduk AM, Gurwitz JH, Tabada G et al. Influence of multimorbidity on burden and appropriateness of implantable cardioverter-defibrillator therapies. J Am Geriatr Soc 2019 Jul; 67:1370. PMID: 30892695
  39. Knops RE et al. Subcutaneous or transvenous defibrillator therapy. N Engl J Med 2020 Aug 6; 383:526 PMID: 32757521 https://www.nejm.org/doi/10.1056/NEJMoa1915932
  40. Greenberg JC, Altawil MR, Singh G Life Saving Therapy Inhibition by Phones Containing Magnets. Heart Rhythm. 2021. Jan 4. PMID: 33418126 https://www.heartrhythmjournal.com/article/S1547-5271(20)31227-3/fulltext
  41. Fery C et al. Magnetic field measurements of portable electronic devices: The risk inside pockets for patients with cardiovascular implantable devices. Circ Arrhythm Electrophysiol 2022 Mar; 15:e010646 PMID: 35227069 https://www.ahajournals.org/doi/10.1161/CIRCEP.121.010646
  42. Heidenreich PA et al. 2022 AHA/ACC/HFSA guideline for the management of heart failure. J Am Coll Cardiol 2022 Apr 1; [e-pub] PMID: 35363499 Review. https://www.sciencedirect.com/science/article/abs/pii/S0735109721083959
  43. Dressler DD MRI in Patients with Non-MRI-Conditional Implantable Defibrillators. NEJM Journal Watch. Feb 2, 2023. https://www.jwatch.org - Ra J et al. Implantable defibrillator system shock function, mortality, and cause of death after magnetic resonance imaging. Ann Intern Med 2023 Jan 31; [e-pub] https://www.acpjournals.org/doi/10.7326/M22-2653
  44. Al-Khatib SM, Stevenson WG, Ackerman MJ et al 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2018 Oct 2;72(14):e91-e220. PMID: 29097296 Free article. Review.
  45. Myerburg RJ Implantable cardioverter-defibrillators after myocardial infarction. N Engl J Med 2008;359:2245-53 PMID: 19020326