Indications:
Benefits:
1) provides basal & meal bolus insulin requirements
2) provides tighter glucose control in selected patients with type 1 diabetes mellitus
3) reduces variability in absorption from injection sites
4) may benefit patients of all ages (including those < 4 years of age) [3]
5) minimizes nocturnal hypoglycemia [5]
6) reduces fatal cardiovascular events (RR=0.58) & all-cause mortality (RR=0.73) relative to daily insulin injections in patients with type 1 diabetes mellitus [8]
Insulin: regular insulin or lisproinsulin
Contraindications:
1) hypoglycemia-induced loss of consciousness
2) cardiovascular disease or cerebrovascular disease
3) seizures
Complications:
1) catheter site infection
2) interruption of insulin delivery with pump malfunction
- ketoacidosis
Mechanism of action:
- subcutaneously implanted insulin pumps provide continuous delivery of insulin (contrast with artificial pancreas)
Clinical trials:
1) Clinical trial comparing insulin pump vs optimized injections [2]
a) average glucose control better with pump (18 mg/dL)
b) average HgbA1c less with pump (0.5%)
c) average total insulin use less with pump (8 units/day)
2) sensor-augmented insulin pump that automatically suspends insulin delivery at a prespecified glucose threshold can reduce the incidence of hypoglycemia [6]
3) closed-loop insulin delivery system [13]
Management:
- decrease insulin dosage if episodes of hypoglycemia, even if glycemic control is poor* [1]
* brittle diabetics may have episodes of hypoglycemia & hyperglycemia; hypoglycemic unawareness is especially problematic
Notes:
- lack of transparency from manufacturers regarding insulin pump safety [7]
- training for patients recommended [7]
- patients should report adverse events [7]
- insulin pumps over-deliver > 1/2 unit on takeoff & under-deliver a somewhat less on landing [14]
Related
diabetes mellitus type 1 (insulin-dependent, juvenile)
Specific
automated closed-loop insulin delivery; automated insulin dosing controller; automated glycemic controller device; artificial pancreas
General
insulin device (device for administering insulin)
infusion pump
References
- Medical Knowledge Self Assessment Program (MKSAP) 11, 14, 17
American College of Physicians, Philadelphia 1998, 2006, 2015.
- Journal Watch 22(10):81, 2002
Pickup J et al
Glycaemic control with continuous subcutaneous insulin
infusion compared with intensive insulin injections in
patients with type 1 diabetes: meta-analysis of randomised
controlled trials.
BMJ 324:705, 2002
PMID: 11909787
- Journal Watch 22(23):175, 2002
Litton J et al
Insulin pump therapy in toddlers and preschool children with
type 1 diabetes mellitus.
J Pediatri 141:490, 2002
PMID: 12378187
- Prescriber's Letter 17(12): 2010
Insulin Pump Therapy
Detail-Document#: 261203
(subscription needed) http://www.prescribersletter.com
- Bergenstal RM et al
Threshold-Based Insulin-Pump Interruption for Reduction of
Hypoglycemia.
N Engl J Med. June 24, 2013
PMID: 23789889
http://www.nejm.org/doi/pdf/10.1056/NEJMoa1303576
- Ly TT, Nicholas JA, Retterath A et al
Effect of Sensor-Augmented Insulin Pump Therapy and Automated
Insulin Suspension vs Standard Insulin Pump Therapy on
Hypoglycemia in Patients With Type 1 Diabetes.
A Randomized Clinical Trial.
JAMA. 2013;310(12):1240-1247
PMID: 24065010
http://jama.jamanetwork.com/article.aspx?articleid=1741822
- Choudhary P
Insulin Pump Therapy With Automated Insulin Suspension.
Toward Freedom From Nocturnal Hypoglycemia.
JAMA. 2013;310(12):1235-1236
PMID: 24065008
ama.jamanetwork.com/article.aspx?articleid=1741800
- Heinemann L et al
Insulin Pump Risks and Benefits:A Clinical Appraisal of Pump
Safety Standards, Adverse Event Reporting, and Research Needs.
A Joint Statement of the European Association for the Study of
Diabetes and the American Diabetes Association Diabetes
Technology Working Group.
Diabetes Care. March 16, 2015
PMID: 25776138
http://care.diabetesjournals.org/content/early/2015/03/13/dc15-0168.full.pdf+html
- Steineck I et al
Insulin pump therapy, multiple daily injections, and
cardiovascular mortality in 18 168 people with type 1 diabetes:
observational study.
BMJ 2015;350:h3234
PMID: 26100640
http://www.bmj.com/content/350/bmj.h3234
- Bergenstal RM, Tamborlane WV, Ahmann A et al
Effectiveness of sensor-augmented insulin-pump therapy in
type 1 diabetes.
N Engl J Med. 2010 Jul 22;363(4):311-20.
PMID: 20587585
- American Diabetes Association.
(6) Glycemic targets.
Diabetes Care. 2015 Jan;38 Suppl:S33-40.
PMID: 25537705
- FDA News Release. Feb 14, 2019
FDA authorizes first interoperable insulin pump intended to allow
patients to customize treatment through their individual diabetes
management devices.
https://www.fda.gov/news-events/press-announcements/fda-authorizes-first-interoperable-insulin-pump-intended-allow-patients-customize-treatment-through
- FDA News Release. Jine 27, 2019
FDA warns patients and health care providers about potential
cybersecurity concerns with certain Medtronic insulin pumps.
https://www.fda.gov/news-events/press-announcements/fda-warns-patients-and-health-care-providers-about-potential-cybersecurity-concerns-certain
- Certain Medtronic MiniMed Insulin Pumps Have Potential Cybersecurity
Risks: FDA Safety Communication June 27, 2019
https://www.fda.gov/medical-devices/safety-communications/certain-medtronic-minimed-insulin-pumps-have-potential-cybersecurity-risks-fda-safety-communication
- Brown SA, Kovatchev BP, Raghinaru D et al.
Six-month randomized, multicenter trial of closed-loop control
in type 1 diabetes.
N Engl J Med 2019 Oct 31; 381:1707-1717
PMID: 31618560
https://www.nejm.org/doi/10.1056/NEJMoa1907863
- Tucker ME
Air Travel Alters Insulin Pump Delivery on Takeoff, Landing.
Medscape.September 27, 2024
https://www.medscape.com/viewarticle/air-travel-alters-insulin-pump-delivery-takeoff-landing-2024a1000hna